Delta VFD 0.4-7.5kw Same Function and Outlook with Delta M Series

Delta VFD 0.4-7.5kw Same Function and Outlook with Delta M Series

VFD-M sequence frequency inverter feature :
Thank you for picking substantial-overall performance VFD-M Series. The VFD-M Series is created with substantial-quality factors and resources and include the latest microprocessor technology CZPT.

Compact sensorless vector micro AC vfd designed for modest &
medium horsepower apps.
★Same Outlook and Operate as Delta L Collection
★Adjustable V/F& vector control Curve
★Carruer Frequency Upto 15KHZ
★Auto Torque Increase & Slip Compensation
★Built in PID Suggestions control
★Built in MODBUS baudrate 38400bps
★0 speed holding function
★Built in Slumber -revival purpose
★24 Months Guarantee

one.1 Specs:

Voltage Course 230V Course
Model Amount VFD-M 0R4 0R7 1R5 2R2 3R7 5R5
Max. Applicable Motor Output (kW) .four .seventy five one.five two.two 3.7 five.five
Max. Relevant Motor Output (hp) .5 1.one two. three. 5. seven.5
OUTPUT Score Rated Output Capacity (kVA) 1. 1.9 two.seven 3.eight six.5 nine.five
Rated Output Existing (A) two.five five. 7. 10 17 25
Greatest Output Voltage (V) 3-period Proportional to Enter Voltage
Output Frequency (Hz) .1~four hundred Hz
Provider Frequency (kHz) 1-fifteen
Input Score Rated Input Current (A) One/three-section three-stage
6.three/two.nine 11.five/7.six fifteen.seven/eight.8 27/12.5 19.6 28
Enter Existing for one-phase
Versions when Utilizing three-stage
Electricity
3.2 6.three 9. 12.5 _ _
Rated Voltage, Frequency One/three-phase
200-240 VAC, fifty/60Hz
three-section
two hundred-240VAC,
fifty/60Hz
Voltage Tolerance ± ten% (one hundred eighty~264 VAC)
Frequency Tolerance ± 5% (47~sixty three Hz)
Cooling Strategy Enthusiast Cooled
Bodyweight (kg) 2.two/one.5 2.2/1.five 2.2/1.five 3.2/2.2 three.two three

 

Voltage Course 460V Course
Design Variety VFD-M 0R7 1R5 2R2 3R7 5R5 7R5
Max. Applicable Motor Output (kW) .75 1.5 2.2 3.seven five.5 seven.five
Max. Relevant Motor Output (hp) one. 2. three. 5. seven.five 10
OUTPUT Rating Rated Output Ability (kVA) two.3 3.1 3.eight 6.2 nine.nine 13.7
Rated Output Present (A) three. 4. 5. eight.2 13 18
Highest Output Voltage (V) three-Stage proportion to 2 times the enter voltage
Output Frequency (Hz) .one~400 Hz
Provider Frequency (kHz) 1-15
Enter Ranking Rated Input Recent (A) three-period
four.two 5.7 six. eight.five 14 23
Rated Voltage, Frequency three-period 380-480 VAC, 50/60Hz
Voltage Tolerance ± 10% (342~528 VAC)
Frequency Tolerance ± 5% (47~sixty three Hz) 
Cooling Technique Supporter Cooled
Fat (kg) one.five one.5 2. three.2 3.2 3.three

1.2 VFD-M Sequence AC Drive Types Listing
 

Product Name Max. Current
(input / output)
Wire Gauge
AWG (mmtwo)
Torque
kgf-cm (in-lbf)
VFD-M-2S-.4G six.3A/two.5A twelve-14 (three.three-2.one) 14
(12)
VFD-M-2T-.4G three.2A/2.5A
VFD-M-2S-.7G 11.5A/5.0A
VFD-M-2T-.7G 6.3A/five.0A
VFD-M-2S-one.5G 15.7A/seven.0A 12 (3.three)
VFD-M-2T-one.5G 9.0A/seven.0A 12-14 (3.three-2.1)
VFD-M-2S-two.2G 27A/10A eight (8.4) fifteen
(13)
VFD-M-2T-two.2G 15A/10A eight-twelve (eight.4-three.3)
VFD-M-2T-3.7G 19.6A/17A 8-ten (eight.4-5.three)
VFD-M-2T-five.5G 28A/25A eight (8.4)
VFD-M-4T-.4G four.2A/three.0A twelve-14 (3.3-two.one) fourteen
(12)
VFD-M-4T-1.5G five.7A/4.0A twelve-fourteen (three.three-two.one)
VFD-M-4T-two.2G 6.0A/5.0A 12-fourteen (three.3-two.1)
VFD-M-4T-3.7G 8.5A/8.2A 8-fourteen (8.four-two.1) 15
(13)
VFD-M-4T-five.5G 14A/13A 8-12 (8.4-3.3)
VFD-M-4T-seven.5G 23A/18A eight-ten (eight.four-5.three)

 

1.three Basic Wiring Diagram

1.4 Ambient Conditions

Set up the AC motor generate in an setting with the subsequent circumstances:

Procedure Air Temperature: -10 ~ +50°C (fourteen ~ 122°F) for UL & cUL
-10 ~ +40°C (fourteen ~ 104°F) for 5.5kw models and previously mentioned
  Relative Humidity: <90%, no condensation allowed
 
  Atmosphere force: 86 ~ 106 kPa
 
  Set up Web site Altitude: <1000m
 
  Vibration: <20Hz: 9.80 m/s2 (1G) max
20 ~ 50Hz: 5.88 m/s2 (.6G) max
Storage
Transportation
Temperature:
Relative
-20°C ~ +60°C (-4°F ~ 140°F
  Humidity: <90%, no condensation allowed
  Ambiance stress: 86 ~ 106 kPa
  Vibration: <20Hz: 9.80 m/s2 (1G) max
20 ~ 50Hz: five.88 m/s2 (.6G) max
Air pollution
Diploma
two: very good for a manufacturing unit kind atmosphere.

one.4 Control Terminal Wiring (Manufacturing facility Configurations)

1.five LC-M02E


Our Support:

one.   Can I get some samples?
Indeed, Sample get is CZPT for top quality examine and marketplace check .But you have to shell out for it .
two.   What is delivery time?
It normally normally takes about 3-5 operating times for little purchase and 10-15 days for big get .
three.   What is actually your payment conditions?
We normally accept all sorts of payment phrases .This kind of as T/T,L/C, Western Union.Cash.
four.   What is your guarantee phrases?
We provide 24 months warranty time .
five.   Do you have the items in inventory?
Is dependent on your request ,We have standard types in inventory. Some specific goods and big order will be newly created according to your get .
six.   Can I mix diverse electrical power in one particular container .
Sure ,Different versions can be combined up in one container ,even one get .
7.   How does your manufacturing facility do the high quality manage?
Good quality is precedence ,we usually connect the importance to top quality manage from the starting to the stop of the manufacturing .each product will be entirely assembled and meticulously analyzed just before packing and delivery .
8.   Can you promote spare areas ?
If you are utilizing our products .we can promote spare parts to you . But we couldn’t promote the fifty percent-completed merchandise.
9.I would like to know if you have a spouse for export?
Indeed .We have the proper to export and can promote electrical merchandise all in excess of the globe..
10. Can you make the inverter and delicate starter manage boards (switchgear)?
Yes. We have a lot of encounter to layout frequency inverter and gentle starter cabinet according to your request . 
11.Can the inverter hook up with computer?
Of course .All inverters have created-in RS485 port .and support Modbus interaction protocol. 
12.How can I have confidence in you ?
Our organization has been audited and approved CZPT,CE.CCC. Assessment report will could be sent to you by e-mail. and we will take all the obligation when problem throughout warranty time.

Delta VFD 0.4-7.5kw Same Function and Outlook with Delta M Series